Steam boiler ARTO/DV

Steam boiler ARTO/DV

Reverse flame tube boilers.

  • Capacity:  1.000 to 1.500 kg/h
  • Design Pressure: 10 bar

ARTO /DV type steam boilers are suitable for all traditional oil and gaseous fuels. They are of vertical jacket type, with double flue gas path. The flame chamber is surrounded by a vertical water-steam jacket with  fins on is outer surface.

Due to the small volume of water inside the boilers, ARTO / DV type boilers fall into category C according to Greek legislation, so there is no requirement for a boiler room of special specifications and no requirement for operation by a qualified operator (heater)!

ARTO / DV boilers are constructed and tested in accordance with the P.E.D 2014/68/EUrelative to the pressure equipment (PED)

Special features

  • Wide furnace with wet back
  • Finned secondary heat transfer surface
  • Large water and steam volume
  • Dry saturated steam
  • Easy maintenance facilitated from :
    • Clamp locks of the water chamber
    • Clamp locks of the furnace
    • Clamp locks for checking the fins
  • Ηigh temperatures ceramic insulation (1600 0C) and coating with DCP sheets.
  • Insulation made of high density mineral wool, protected by aluminium steel sheet
  • Low fuel consumption
  • High efficiency up to 91%. The use of an economizer can increase the boiler efficiency even more than up to 96%
  • Durability

Standard equipment

  • Pre-wired electrical control panel
  • Feed water pump(s)
  • Feed water control with conductivity probes
  • Low level conductivity probe
  • Steam working pressure limiter
  • Second working steam pressure limiter for the modulating operation of the burner.
  • Steam safety pressure limiter
  • Main steam valve bellow sealed type
  • Full stroke safety valve spring type
  • Angular feed water valve bellow sealed type
  • Inox non return disk valve for the water feed inlet
  • Steam valve bellow sealed type before the bottom blow down valve
  • Manual blow down valve
  • Reflex level indicator
  • Special set of valves for the water level gauge which close immediately automatically in case the sight glass brakes. 
  • 3-way valve for the water level gauge for drainage and water sample
  • Pressure gauge
  • Deaeration valve for the boiler 
  • Glycerin manometer  for the water inlet pressure after the pump
  • Stainless steel needle valve for water sampling

 

Optional equipment on demand

  • A multi level electronic electrode 4-20 mA for automatic water level control
  • Self checked low level safety electrode according to TRD 604/24 h for 24 hour operation without supervision. 
  • Automatic surface blow down valve according to TRD 604/24 h for 24 hour operation without supervision. 
  • Automatic pneumatic bottom blow down valve.
  • Inverter on the feed water pump for the full modulation of the water that goes in the boiler.
  • Extra reflex level indicator
  • Extra safety valve

Apart the above mentioned armatures of the boiler, ARTEMIS can also provide all

 

Peripherical equipment of a boiler- house

  • Economizer
  • Feed water tank for partial or full deaeration
  • Water treatment system
  • Blow down vessel
  • Stack
  • Feed water pump module
  • Steam distributor
  • Pre-assembled components for steam lines
  • Oil preheater
  • Domestic Hot Water (DHW) heater